diff options
| author | Claude <noreply@anthropic.com> | 2026-10-19 09:15:03 +0000 |
|---|---|---|
| committer | Claude <noreply@anthropic.com> | 2026-10-19 09:15:03 +0000 |
| commit | 10abc31e8220b39231cac31ee96109071c56c950 (patch) | |
| tree | f914eb6ddf47b974547d85376c6be185627a3923 /server | |
| parent | d96c876752e95a17169d18729dd1897d2dc5731f (diff) | |
Record that lowering the noise floor to 8s is wrong
The 12s floor cut real detection on shows with verified ads -- LeVar
Burton Reads fell from 19.0 to 10.5 minutes found against a 26.6 minute
gap -- so 8s looked like the fix. Measured on an isolated copy of the
live data it is not: Sleepy History at 8s finds 174 minutes of
"advertising" in a show that has 48 seconds of it, worse than the 4s
floor that produced Peter's original complaint.
MinRunSamples and MergeGapMs interact and cannot be tuned separately. A
low floor lets noise fragments survive and the 60s bridging then welds
them into enormous spans.
Had only LeVar been measured the floor would have been lowered.
Also re-pins .coverage-baseline, which the hook left modified after
d96c876 deleted covered readout code.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_018AwnALZL6bD4VBtATDVv3B
Diffstat (limited to 'server')
0 files changed, 0 insertions, 0 deletions